Masuda filter FR
Home > Fluid Machinery > Filter > Masuda filter >
![]() |
◆ Features ● Compact and lightweight. (About half compared with conventional VLM type) ● Compact and high performance. ● Easy internal structure and low flow resistance. ● Clogging detector device can be installed as desired. (Option) ● Can be installed on top of tank. ● Mounting flange for the case is prepared separately. ■ When using hydraulic fluid other than mineral oil, please specify as material, packing etc. will change . ● Maximum operating pressure 1 MPa ● Test pressure 1.5 MPa |
Model number code
※ - FR * 12 - 10P 12F ┃ ┃ ┃ ┃ ┃ ┃Fluid type ModelAccessory Series No. Element accuracy Connection port size (micron display) Connection methodElement material
■ kind of fluid
symbol | fluid |
Nil | General mineral oil |
W | Water-glycol type |
F | Phosphate ester type |
■ Accessories
symbol | accessories |
Nil | No accessories |
S | Clogging detector |
E | With electrical contact |
■ Port size, connection method, flow rate table (kinematic viscosity 50 m / s, 10 μ paper)
Type expression | Connection port diameter | Connection method |
Flow rate L / min |
||
IN side Rc |
OUT side | ||||
Rc | Flange | ||||
FR04-04T | 1/2 | 1/2 | - |
Standard product: IN - threaded type FF: IN, OUT - flanged type T: OUT - threaded type F: OUT - flange type |
30 |
FR06-06T | 3/4 | 3/4 | - | 70 | |
FR08-08T | 1 | 1 | - | 100 | |
FR 10 - 10 F | 1 1/4 | - | 32 A | 150 | |
FR12-12F | 1 1/2 | - | 40 A | 280 | |
FR 16-16 F | 2 | - | 50 A | 500 | |
FR 20 - 20 F | 2 1/2 | - | 65 A | 700 | |
FR24-24F | 3 | - | 80 A | 800 |
■ element accuracy Material
Element precision Production range |
Element material |
5 ~ 400μ | S (stainless steel wire mesh) |
3, 5, 10, 20, 40 μ |
P (paper) |